SITOP PSU8200 24 V/5 A stabilized power supply input: 120/230 V AC output: 24 V DC/5 A

SITOP PSU8200 24 V/5 A stabilized power supply input: 120/230 V AC output: 24 V DC/5 A


Specifications
SKU
6EP3333-8SB00-0AY0
Details

input
type of the power supply network 1-phase AC
supply voltage at AC Automatic range selection
supply voltage 120 V/230 V
input voltage 1 at AC 85 ... 132 V
input voltage 2 at AC 170 ... 264 V
wide range input No
buffering time for rated value of the output current in the event of power failure minimum 35 ms
operating condition of the mains buffering at Vin = 120/230 V
line frequency 50/60 Hz
line frequency 47 ... 63 Hz
input current  
● at rated input voltage 120 V 2.1 A
● at rated input voltage 230 V 1.2 A
current limitation of inrush current at 25 °C maximum 10 A
I2t value maximum 0.2 A²·s
fuse protection type T 3.15 A (not accessible)
fuse protection type in the feeder Recommended miniature circuit breaker at 1-phase operation: from 6 A (10 A) characteristic C (B); required at 2-phase operation: circuit breaker 2-pole connected or circuit breaker 3RV2011-1EA10 (setting 3.8 A) or 3RV2711-1ED10 (UL 489) at 230 V; 3RV2011-1DA10 (setting 3 A) or 3RV2711-1DD10 (UL 489) at 400/500 V
output
voltage curve at output Controlled, isolated DC voltage
output voltage at DC rated value 24 V
output voltage  
● at output 1 at DC rated value 24 V
   
output voltage adjustable Yes; via potentiometer
adjustable output voltage 24 ... 28.8 V; max. 120 W
relative overall tolerance of the voltage 3 %
relative control precision of the output voltage  
● on slow fluctuation of input voltage 0.1 %
● on slow fluctuation of ohm loading 0.2 %
residual ripple  
● maximum 50 mV
voltage peak  
● maximum 200 mV
display version for normal operation Green LED for 24 V OK
type of signal at output Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"
behavior of the output voltage when switching on Overshoot of Vout approx. 3 %
response delay maximum 1.5 s
voltage increase time of the output voltage  
● typical 30 ms
output current  
● rated value 5 A
● rated range 0 ... 5 A; As of Ua>24 V: 4% [Ia]/V [Ua]; at Ue<100 V/<200 V: 80% Ia rated
   
supplied active power typical 120 W
short-term overload current  
● at short-circuit during operation typical 15 A
duration of overloading capability for excess current  
● at short-circuit during operation 25 ms
constant overload current  
● on short-circuiting during the start-up typical 6 A
bridging of equipment Yes; switchable characteristic
number of parallel-switched equipment resources for increasing the power 2
efficiency
efficiency in percent 93 %
power loss [W]  
● at rated output voltage for rated value of the output current typical 9 W
● during no-load operation maximum 1.5 W
closed-loop control
relative control precision of the output voltage with rapid fluctuation of the input voltage by +/- 15% typical 0.1 %
relative control precision of the output voltage load step of resistive load 50/100/50 % typical 2 %
setting time  
● load step 50 to 100% typical 0.25 ms
● load step 100 to 50% typical 0.5 ms
relative control precision of the output voltage at load step of resistive load 10/90/10 % typical 2 %
setting time  
● load step 10 to 90% typical 0.25 ms
● load step 90 to 10% typical 0.5 ms
● maximum 1 ms
protection and monitoring
design of the overvoltage protection < 33 V
property of the output short-circuit proof Yes
design of short-circuit protection Alternatively, constant current characteristic approx. 6 A or latching shutdown
● typical 6 A
overcurrent overload capability  
● in normal operation overload capability 150 % Iout rated up to 5 s/min
enduring short circuit current RMS value  
● typical 6 A
display version for overload and short circuit LED yellow for "overload", LED red for "latching shutdown"
safety
galvanic isolation between input and output Yes
galvanic isolation Safety extra-low output voltage Uout acc. to EN 60950-1 and EN 50178
operating resource protection class Class I
leakage current  
● maximum 3.5 mA
● typical 1 mA
protection class IP IP20
EMC
standard  
● for emitted interference EN 55022 Class B
● for mains harmonics limitation EN 61000-3-2
● for interference immunity EN 61000-6-2
standards, specifications, approvals
certificate of suitability  
● CE marking Yes
● UL approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)
● CSA approval Yes; cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259; cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)
● EAC approval Yes
● Regulatory Compliance Mark (RCM) Yes
● NEC Class 2 No
type of certification  
● BIS Yes; R-41183539
● CB-certificate Yes
MTBF at 40 °C 1 421 519 h
standards, specifications, approvals hazardous environments
certificate of suitability  
● IECEx No
● ATEX No
● ULhazloc approval No
● cCSAus, Class 1, Division 2 No
● FM registration No
standards, specifications, approvals marine classification
shipbuilding approval Yes
Marine classification association  
● American Bureau of Shipping Europe Ltd. (ABS) Yes
● French marine classification society (BV) No
● Det Norske Veritas (DNV) Yes
● Lloyds Register of Shipping (LRS) No
standards, specifications, approvals Environmental Product Declaration
Environmental Product Declaration Yes
global warming potential [CO2 eq]  
● total 294.6 kg
● during manufacturing 12.6 kg
● during operation 281.6 kg
● after end of life 0.18 kg
ambient conditions
ambient temperature  
● during operation -25 ... +70 °C; With natural convection; startup tested starting from -40 °C nominal voltage
● during transport -40 ... +85 °C
● during storage -40 ... +85 °C
environmental category according to IEC 60721 Climate class 3K3, 5 ... 95% no condensation
connection method
type of electrical connection screw terminal
● at input L, N, PE: 1 screw terminal each for 0.2 ... 2.5 mm² single-core/finely stranded
● at output +, -: 2 screw terminals each for 0.2 ... 2.5 mm²
● for auxiliary contacts 13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm²; 15, 16 (Remote): 1 screw terminal each for 0.14 ... 1.5 mm²
mechanical data
width × height × depth of the enclosure 45 × 125 × 125 mm
installation width × mounting height 45 mm × 225 mm
required spacing  
● top 50 mm
● bottom 50 mm
● left 0 mm
● right 0 mm
fastening method Snaps onto DIN rail EN 60715 35x7.5/15
● DIN-rail mounting Yes
● S7 rail mounting No
● wall mounting No
housing can be lined up Yes
net weight 0.8 kg

View more about SITOP PSU8200 24 V/5 A stabilized power supply input: 120/230 V AC output: 24 V DC/5 A on main site