Circuit breaker size S0 for motor protection, CLASS 10 A-release 27...32 A N-release 400 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC
Category: SIEMENS Simatic Control Systems
Specifications
SKU
3RV2021-4EA15
Details
| product brand name | SIRIUS | |
| product designation | Circuit breaker | |
| design of the product | For motor protection | |
| product type designation | 3RV2 | |
| General technical data | ||
| size of the circuit-breaker | S0 | |
| size of contactor can be combined company-specific | S00, S0 | |
| product extension auxiliary switch | Yes | |
| power loss [W] for rated value of the current | ||
| ● at AC in hot operating state | 13.25 W | |
| ● at AC in hot operating state per pole | 4.4 W | |
| insulation voltage with degree of pollution 3 at AC rated value | 690 V | |
| surge voltage resistance rated value | 6 kV | |
| shock resistance according to IEC 60068-2-27 | 25g / 11 ms | |
| mechanical service life (operating cycles) | ||
| ● of the main contacts typical | 100 000 | |
| ● of auxiliary contacts typical | 100 000 | |
| electrical endurance (operating cycles) typical | 100 000 | |
| reference code according to IEC 81346-2 | Q | |
| Substance Prohibitance (Date) | 10/01/2009 | |
| SVHC substance name | Lead - 7439-92-1 Lead titanium zirconium oxide - 12626-81-2 |
|
| Weight | 0.395 kg | |
| Ambient conditions | ||
| installation altitude at height above sea level maximum | 2 000 m | |
| ambient temperature | ||
| ● during operation | -20 ... +60 °C | |
| ● during storage | -50 ... +80 °C | |
| ● during transport | -50 ... +80 °C | |
| relative humidity during operation | 10 ... 95 % | |
| Environmental footprint | ||
| Environmental Product Declaration(EPD) | Yes | |
| global warming potential [CO2 eq] total | 75.078 kg | |
| global warming potential [CO2 eq] during manufacturing | 2.68 kg | |
| global warming potential [CO2 eq] during sales | 0.143 kg | |
| global warming potential [CO2 eq] during operation | 72.7 kg | |
| global warming potential [CO2 eq] after end of life | -0.445 kg | |
| Siemens Eco Profile (SEP) | Siemens EcoTech | |
| Main circuit | ||
| number of poles for main current circuit | 3 | |
| adjustable current response value current of the current-dependent overload release | 27 ... 32 A | |
| type of voltage for main current circuit | AC | |
| operating voltage | ||
| ● rated value | 20 ... 690 V | |
| ● at AC-3 rated value maximum | 690 V | |
| ● at AC-3e rated value maximum | 690 V | |
| operating frequency rated value | 50 ... 60 Hz | |
| operational current rated value | 32 A | |
| operational current | ||
| ● at AC-3 at 400 V rated value | 32 A | |
| ● at AC-3e at 400 V rated value | 32 A | |
| operating power | ||
| ● at AC-3 | ||
| — at 230 V rated value | 7.5 kW | |
| — at 400 V rated value | 15 kW | |
| — at 500 V rated value | 18.5 kW | |
| — at 690 V rated value | 30 kW | |
| ● at AC-3e | ||
| — at 230 V rated value | 7.5 kW | |
| — at 400 V rated value | 15 kW | |
| — at 500 V rated value | 18.5 kW | |
| — at 690 V rated value | 30 kW | |
| operating frequency | ||
| ● at AC-3 maximum | 15 1/h | |
| ● at AC-3e maximum | 15 1/h | |
| Auxiliary circuit | ||
| design of the auxiliary switch | transverse | |
| type of voltage for auxiliary and control circuit | AC/DC | |
| number of NC contacts for auxiliary contacts | 1 | |
| number of NO contacts for auxiliary contacts | 1 | |
| number of CO contacts for auxiliary contacts | 0 | |
| operational current of auxiliary contacts at AC-15 | ||
| ● at 24 V | 2 A | |
| ● at 120 V | 0.5 A | |
| ● at 125 V | 0.5 A | |
| ● at 230 V | 0.5 A | |
| operational current of auxiliary contacts at DC-13 | ||
| ● at 24 V | 1 A | |
| ● at 60 V | 0.15 A | |
| Protective and monitoring functions | ||
| product function | ||
| ● ground fault detection | No | |
| ● phase failure detection | Yes | |
| trip class | CLASS 10 | |
| design of the overload release | thermal | |
| maximum short-circuit current breaking capacity (Icu) | ||
| ● at AC at 240 V rated value | 100 kA | |
| ● at AC at 400 V rated value | 55 kA | |
| ● at AC at 500 V rated value | 10 kA | |
| ● at AC at 690 V rated value | 4 kA | |
| operating short-circuit current breaking capacity (Ics) at AC | ||
| ● at 240 V rated value | 100 kA | |
| ● at 400 V rated value | 25 kA | |
| ● at 500 V rated value | 5 kA | |
| ● at 690 V rated value | 2 kA | |
| response value current of instantaneous short-circuit trip unit | 400 A | |
| UL/CSA ratings | ||
| full-load current (FLA) for 3-phase AC motor | ||
| ● at 480 V rated value | 32 A | |
| ● at 600 V rated value | 32 A | |
| yielded mechanical performance [hp] | ||
| ● for single-phase AC motor | ||
| — at 110/120 V rated value | 2 hp | |
| — at 230 V rated value | 5 hp | |
| ● for 3-phase AC motor | ||
| — at 200/208 V rated value | 7.5 hp | |
| — at 220/230 V rated value | 10 hp | |
| — at 460/480 V rated value | 20 hp | |
| contact rating of auxiliary contacts according to UL | C300 / R300 | |
| Short-circuit protection | ||
| product function short circuit protection | Yes | |
| design of the short-circuit trip | magnetic | |
| design of the fuse link | ||
| ● for short-circuit protection of the auxiliary switch required | Fuse gL/gG: 10 A, miniature circuit breaker C 6 A (short-circuit current Ik < 400 A) | |
| design of the fuse link for IT network for short-circuit protection of the main circuit | ||
| ● at 400 V | gL/gG 63 A | |
| ● at 500 V | gL/gG 63 A | |
| ● at 690 V | gL/gG 63 A | |
| Installation/ mounting/ dimensions | ||
| mounting position | any | |
| fastening method | screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 | |
| height | 97 mm | |
| width | 45 mm | |
| depth | 97 mm | |
| required spacing | ||
| ● with side-by-side mounting at the side | 0 mm | |
| ● for grounded parts at 400 V | ||
| — downwards | 30 mm | |
| — upwards | 30 mm | |
| — at the side | 9 mm | |
| ● for live parts at 400 V | ||
| — downwards | 30 mm | |
| — upwards | 30 mm | |
| — at the side | 9 mm | |
| ● for grounded parts at 500 V | ||
| — downwards | 30 mm | |
| — upwards | 30 mm | |
| — at the side | 9 mm | |
| ● for live parts at 500 V | ||
| — downwards | 30 mm | |
| — upwards | 30 mm | |
| — at the side | 9 mm | |
| ● for grounded parts at 690 V | ||
| — downwards | 50 mm | |
| — upwards | 50 mm | |
| — backwards | 0 mm | |
| — at the side | 30 mm | |
| — forwards | 0 mm | |
| ● for live parts at 690 V | ||
| — downwards | 50 mm | |
| — upwards | 50 mm | |
| — backwards | 0 mm | |
| — at the side | 30 mm | |
| — forwards | 0 mm | |
| Connections/ Terminals | ||
| type of electrical connection | ||
| ● for main current circuit | screw-type terminals | |
| ● for auxiliary and control circuit | screw-type terminals | |
| arrangement of electrical connectors for main current circuit | Top and bottom | |
| type of connectable conductor cross-sections | ||
| ● for main contacts | ||
| — solid or stranded | 2x (1 ... 2.5 mm²), 2x (2.5 ... 10 mm²) | |
| — finely stranded with core end processing | 2x (1 ... 2.5 mm²), 2x (2.5 ... 6 mm²), 1x 10 mm² | |
| ● for AWG cables for main contacts | 2x (16 ... 12), 2x (14 ... 8) | |
| type of connectable conductor cross-sections | ||
| ● for auxiliary contacts | ||
| — solid or stranded | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) | |
| — finely stranded with core end processing | 2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²) | |
| ● for AWG cables for auxiliary contacts | 2x (20 ... 16), 2x (18 ... 14) | |
| tightening torque | ||
| ● for main contacts with screw-type terminals | 2 ... 2.5 N·m | |
| ● for auxiliary contacts with screw-type terminals | 0.8 ... 1.2 N·m | |
| design of screwdriver shaft | Diameter 5 to 6 mm | |
| size of the screwdriver tip | Pozidriv size 2 | |
| design of the thread of the connection screw | ||
| ● for main contacts | M4 | |
| ● of the auxiliary and control contacts | M3 | |
| Safety related data | ||
| product function suitable for safety function | Yes | |
| suitability for use | ||
| ● safety-related switching on | No | |
| ● safety-related switching OFF | Yes | |
| service life maximum | 10 a | |
| test wear-related service life necessary | Yes | |
| proportion of dangerous failures | ||
| ● with low demand rate according to SN 31920 | 40 % | |
| ● with high demand rate according to SN 31920 | 50 % | |
| B10 value with high demand rate according to SN 31920 | 5 000 | |
| failure rate [FIT] with low demand rate according to SN 31920 | 50 FIT | |
| ISO 13849 | ||
| device type according to ISO 13849-1 | 3 | |
| overdimensioning according to ISO 13849-2 necessary | Yes | |
| IEC 61508 | ||
| safety device type according to IEC 61508-2 | Type A | |
| T1 value | ||
| ● for proof test interval or service life according to IEC 61508 | 10 a | |
| Electrical Safety | ||
| protection class IP on the front according to IEC 60529 | IP20 | |
| touch protection on the front according to IEC 60529 | finger-safe, for vertical contact from the front | |
| Display | ||
| display version for switching status | Handle | |