SIMATIC ET 200SP, Relay module, RQ NO 4x 120V DC..230VAC/5A ST. 4 normally open contacts, isolated contacts, packing unit: 1 piece, fits to BU-type B0 and B1, Colour Code CC40, substitute value output, module diagnostics for: supply voltage

SIMATIC ET 200SP, Relay module, RQ NO 4x 120V DC..230VAC/5A ST. 4 normally open contacts, isolated contacts, packing unit: 1 piece, fits to BU-type B0 and B1, Colour Code CC40, substitute value output, module diagnostics for: supply voltage


Specifications
SKU
6ES7132-6HD01-0BB1
Details

General information
Product type designation RQ 4x120 VDC ... 230 VAC/5 A NO ST
HW functional status From FS02
Firmware version V0.0
● FW update possible No
usable BaseUnits BU type B0, B1
Product function
● I&M data Yes; I&M0 to I&M3
● Isochronous mode No
Engineering with
● STEP 7 TIA Portal configurable/integrated from version V14
● STEP 7 configurable/integrated from version V5.5 SP3
● PCS 7 configurable/integrated from version V8.1 SP1
● PROFIBUS from GSD version/GSD revision One GSD file each, Revision 3 and 5 and higher
● PROFINET from GSD version/GSD revision GSDML V2.3
Operating mode
● DQ Yes
● DQ with energy-saving function No
● PWM No
● Oversampling No
● MSO No
Redundancy
● Redundancy capability Yes
Supply voltage
Rated value (DC) 24 V
permissible range, lower limit (DC) 19.2 V
permissible range, upper limit (DC) 28.8 V
Reverse polarity protection Yes
Input current
Current consumption (rated value) 55 mA; without load
output voltage / header
Rated value (AC) 230 V
Power loss
Power loss, typ. 1.5 W
Address area
Address space per module
● Inputs + 1 byte for QI information
● Outputs 1 byte
Hardware configuration
Automatic encoding Yes
● Mechanical coding element Yes
● Type of mechanical coding element type C
Selection of BaseUnit for connection variants
● 2-wire connection BU type B1
● 3-wire connection BU type B0
Digital outputs
Type of digital output Relays
Number of digital outputs 4
Current-sinking Yes
Current-sourcing Yes
Digital outputs, parameterizable Yes
Short-circuit protection No
Parallel switching of two outputs
● for logic links Yes
● for uprating No
● for redundant control of a load Yes
Switching frequency
● with resistive load, max. 2 Hz
● with inductive load (acc. to IEC 60947-5-1, DC13), max. 0.5 Hz; provide one freewheeling diode for switching frequencies higher than 0.1 Hz
● with inductive load (acc. to IEC 60947-5-1, AC15), max. 0.5 Hz
● on lamp load, max. 2 Hz
Total current of the outputs
● Current per channel, max. 5 A
● Current per module, max. 20 A
Total current of the outputs (per module)
horizontal installation
— up to 50 °C, max. 20 A
— up to 60 °C, max. 16 A
vertical installation
— up to 40 °C, max. 20 A
— up to 50 °C, max. 16 A
Relay outputs
● Number of relay outputs 4
● Rated supply voltage of relay coil L+ (DC) 24 V
● Current consumption of relays (coil current of all relays), max. 40 mA
● external protection for relay outputs Yes, with miniature fuse max. 6 A tripping current and quick-response tripping characteristic
● Number of operating cycles, max. 7 000 000; see additional description in the manual
Switching capacity of contacts
— with inductive load, max. 2 A; see additional description in the manual
— with resistive load, max. 5 A; see additional description in the manual
— Thermal continuous current, max. 5 A; Max. 1 385 VA, 150 W
— Switching current, min. 100 mA; 5 V DC
— Rated switching voltage (DC) 24 V DC to 120 V DC
— Rated switching voltage (AC) 24V AC to 230V AC
Cable length
● shielded, max. 1 000 m
● unshielded, max. 200 m
Interrupts/diagnostics/status information
Diagnostics function Yes
Substitute values connectable Yes
Alarms
● Diagnostic alarm Yes
Diagnoses
● Monitoring the supply voltage Yes
● Wire-break No
● Short-circuit No
Diagnostics indication LED
● Monitoring of the supply voltage (PWR-LED) Yes; green PWR LED
● Channel status display Yes; green LED
● for channel diagnostics No
● for module diagnostics Yes; green/red DIAG LED
Potential separation
Potential separation channels
● between the channels Yes
● between the channels and backplane bus Yes
● between the channels and the power supply of the electronics Yes
Permissible potential difference
between channels and backplane bus/supply voltage 240 V AC
Isolation
Isolation tested with 2 500 V DC (type test)
tested with
● between channels and backplane bus/supply voltage 2 500 V DC
● between backplane bus and supply voltage 707 V DC (type test)
Standards, approvals, certificates
Suitable for safety functions No
Ecological footprint
● environmental product declaration Yes
Global warming potential
— global warming potential, (total) [CO2 eq] 25.5 kg
— global warming potential, (during production) [CO2 eq] 3.54 kg
— global warming potential, (during operation) [CO2 eq] 22.1 kg
— global warming potential, (after end of life cycle) [CO2 eq] -0.137 kg
Ambient conditions
Ambient temperature during operation
● horizontal installation, min. -30 °C
● horizontal installation, max. 60 °C
● vertical installation, min. -30 °C
● vertical installation, max. 50 °C
Altitude during operation relating to sea level
● Installation altitude above sea level, max. 2 000 m; On request: Installation altitudes greater than 2 000 m
Dimensions
Width 20 mm
Height 73 mm
Depth 58 mm
Weights
Weight, approx. 40 g

View more about SIMATIC ET 200SP, Relay module, RQ NO 4x 120V DC..230VAC/5A ST. 4 normally open contacts, isolated contacts, packing unit: 1 piece, fits to BU-type B0 and B1, Colour Code CC40, substitute value output, module diagnostics for: supply voltage on main site