SIMATIC ET 200SP, Analog input module, AI 8XI 2-/4-wire Basic, suitable for BU type A0, A1, Color code CC01, Module diagnostics, 16 bit
Category: SIEMENS Simatic Control Systems
Specifications
SKU
6ES7134-6GF00-0AA1
Details
| General information | ||
| Product type designation | AI 8xI 2-/4-wire BA | |
| HW functional status | FS23 or higher | |
| Firmware version | V2.0.0 | |
| ● FW update possible | Yes | |
| usable BaseUnits | BU type A0, A1 | |
| Color code for module-specific color identification plate | CC01 | |
| Product function | ||
| ● I&M data | Yes; I&M0 to I&M3 | |
| ● Isochronous mode | No | |
| ● Measuring range scalable | No | |
| Engineering with | ||
| ● STEP 7 TIA Portal configurable/integrated from version | TIA Portal V21 | |
| ● STEP 7 configurable/integrated from version | V5.7 SP3 | |
| ● PROFIBUS from GSD version/GSD revision | One GSD file each, Revision 3 and 5 and higher | |
| ● PROFINET from GSD version/GSD revision | GSDML V2.45 | |
| Operating mode | ||
| ● Oversampling | No | |
| ● MSI | No | |
| CiR - Configuration in RUN | ||
| Reparameterization possible in RUN | No | |
| Calibration possible in RUN | No | |
| Supply voltage | ||
| Rated value (DC) | 24 V | |
| permissible range, lower limit (DC) | 19.2 V | |
| permissible range, upper limit (DC) | 28.8 V | |
| Reverse polarity protection | Yes | |
| Input current | ||
| Current consumption (rated value) | 25 mA; rated voltage, all channels active, no load | |
| Current consumption, max. | 725 mA; worst case voltage, all channels active, max. load, no derating | |
| Encoder supply | ||
| 24 V encoder supply | ||
| ● 24 V | Yes | |
| ● Short-circuit protection | Yes | |
| ● Output current, max. | 0.7 A; total current of all encoders/channels | |
| Power loss | ||
| Power loss, typ. | 0.7 W; rated voltage, 50 % active channels, 50 % of range | |
| Address area | ||
| Address space per module | ||
| ● Address space per module, max. | 16 byte | |
| Hardware configuration | ||
| Automatic encoding | Yes | |
| ● Mechanical coding element | Yes | |
| ● Type of mechanical coding element | Type A | |
| Selection of BaseUnit for connection variants | ||
| ● 1-wire connection | BU type A0, A1 | |
| ● 2-wire connection | BU type A0, A1 | |
| ● 4-wire connection | BU type A0, A1 + potential distributor module | |
| Analog inputs | ||
| Number of analog inputs | 8; Single-ended | |
| ● For current measurement | 8 | |
| permissible input current for current input (destruction limit), max. | 50 mA | |
| Cycle time (all channels), min. | 1 ms; per channel | |
| Input ranges (rated values), currents | ||
| ● 0 to 20 mA | Yes | |
| — Input resistance (0 to 20 mA) | 100 Ω; 15 bit | |
| ● -20 mA to +20 mA | Yes | |
| — Input resistance (-20 mA to +20 mA) | 100 Ω; 16 bit incl. sign | |
| ● 4 mA to 20 mA | Yes | |
| — Input resistance (4 mA to 20 mA) | 100 Ω; 15 bit | |
| Cable length | ||
| ● shielded, max. | 200 m | |
| Analog value generation for the inputs | ||
| Integration and conversion time/resolution per channel | ||
| ● Resolution with overrange (bit including sign), max. | 16 bit | |
| ● Integration time, parameterizable | Yes | |
| ● Interference voltage suppression for interference frequency f1 in Hz | 16.67 / 50 / 60 / 4 800 (16.67 / 50 / 60) | |
| ● Conversion time (per channel) | 180 / 60 / 50 / 0.625 (67.5 / 22.5 / 18.75) ms | |
| Smoothing of measured values | ||
| ● Number of smoothing levels | 4 | |
| ● parameterizable | Yes | |
| ● Step: None | Yes | |
| ● Step: low | Yes; 4x smoothing | |
| ● Step: Medium | Yes; 8x smoothing | |
| ● Step: High | Yes; 16x smoothing | |
| Encoder | ||
| Connection of signal encoders | ||
| ● for voltage measurement | No | |
| ● for current measurement as 2-wire transducer | Yes | |
| — Burden of 2-wire transmitter, max. | 650 Ω | |
| ● for current measurement as 4-wire transducer | Yes | |
| Errors/accuracies | ||
| Linearity error (relative to input range), (+/-) | 0.01 % | |
| Temperature error (relative to input range), (+/-) | 0.005 %/K | |
| Crosstalk between the inputs, min. | 50 dB | |
| Repeat accuracy in steady state at 25 °C (relative to input range), (+/-) | 0.05 % | |
| Operational error limit in overall temperature range | ||
| ● Current, relative to input range, (+/-) | 0.5 % | |
| Basic error limit (operational limit at 25 °C) | ||
| ● Current, relative to input range, (+/-) | 0.3 % | |
| Interference voltage suppression for f = n x (f1 +/- 1 %), f1 = interference frequency | ||
| ● Series mode interference (peak value of interference < rated value of input range), min. | 70 dB; With conversion time 67.5 / 22.5 / 18.75 ms: 40 dB | |
| Interrupts/diagnostics/status information | ||
| Diagnostics function | Yes | |
| Alarms | ||
| ● Diagnostic alarm | Yes | |
| ● Limit value alarm | No | |
| Diagnoses | ||
| ● Monitoring the supply voltage | Yes | |
| ● Wire-break | Yes; at 4 to 20 mA | |
| ● Short-circuit | Yes; Sensor supply to M; module by module | |
| ● Group error | Yes | |
| ● Overflow/underflow | Yes; Module-wise | |
| Diagnostics indication LED | ||
| ● Monitoring of the supply voltage (PWR-LED) | Yes; green LED | |
| ● Channel status display | Yes; green LED | |
| ● for channel diagnostics | No | |
| ● for module diagnostics | Yes; green/red DIAG LED | |
| Potential separation | ||
| Potential separation channels | ||
| ● between the channels | No | |
| ● between the channels and backplane bus | Yes | |
| ● between the channels and the power supply of the electronics | No | |
| Isolation | ||
| Isolation tested with | 707 V DC (type test) | |
| Standards, approvals, certificates | ||
| Ecological footprint | ||
| ● environmental product declaration | Yes | |
| Global warming potential | ||
| — global warming potential, (total) [CO2 eq] | 9.32 kg | |
| — global warming potential, (during production) [CO2 eq] | 4.97 kg | |
| — global warming potential, (during operation) [CO2 eq] | 4.79 kg | |
| — global warming potential, (after end of life cycle) [CO2 eq] | -0.449 kg | |
| product functions / security / header | ||
| signed firmware update | Yes; firmware V2.0.0 or higher | |
| safely removing data | Yes; firmware V2.0.0 or higher | |
| data integrity | Yes; firmware V2.0.0 or higher | |
| Ambient conditions | ||
| Ambient temperature during operation | ||
| ● horizontal installation, min. | -30 °C; < 0 °C as of FS04 | |
| ● horizontal installation, max. | 60 °C | |
| ● vertical installation, min. | -30 °C; < 0 °C as of FS04 | |
| ● vertical installation, max. | 50 °C | |
| Altitude during operation relating to sea level | ||
| ● Installation altitude above sea level, max. | 5 000 m; restrictions for installation altitudes > 2 000 m, see ET 200SP system manual | |
| Dimensions | ||
| Width | 15 mm | |
| Height | 73 mm | |
| Depth | 58 mm | |
| Weights | ||
| Weight, approx. | 31 g | |
View more about SIMATIC ET 200SP, Analog input module, AI 8XI 2-/4-wire Basic, suitable for BU type A0, A1, Color code CC01, Module diagnostics, 16 bit on main site